The IRis-core – turnkey mid-IR dual-comb source

The advantages of dual-comb spectroscopy, now also in your application

Dual-comb spectroscopy is increasingly employed in stand-off detection, open path detection and other applications due to its merits in speed, suppression of background radiation and high optical powers.

The IRis-core is an ideal basis for the setup of such a system in the mid-IR range: It offers two overlapping free-running QCL-based frequency comb lasers in a single system. The system outputs already co-aligned beams and comes with a set of drive instructions with factory-characterized heterodyning conditions. The system comes complete with drive electronics and a control computer with a graphical user interface.

IRis-core: high power modular dual-comb source for the mid infrared range.

Modular approach

IRis-core: high power modular dual-comb source for the mid infrared range.

The IRis-core is a receiving bay and driving and control electronics for IRsweep laser modules. In this modular approach, it is possible to exchange the dual-comb laser modules to switch laser wavelength.

The laser modules are compatible with the laser modules of IRsweep’s IRis-F1 dual-comb spectrometer and ensure maximum flexibility in future applications. Suitable detection systems with data-processing capabilities that are integrated can also be provided with the system.

Optional detection system

The IRis-detect is an optional detection system that is available for the IRis-core. It consists of two high bandwidth thermoelectrically cooled MCT detectors for sample and reference channels along with a fast sampling system to collect, process and store the multi-heterodyne data. Data can be processed and represented as transmission or absorption by the system and triggering and typical measurement schemes are readily available. Examples are short time-resolved acquisitions covering time ranges from microseconds to tens of milliseconds and time-averaged data that can be acquired over longer time scales.

Processing is done live on the detection system, which is a requirement to achieve long measurements beyond tens of milliseconds, due to very large raw data rates. Data processing includes a proprietary coherent averaging algorithm optimized to reduce systematic errors including QCL specific drift correction and comb state analysis. The final data is stored in the open HDF5 format. The detection system is controlled through a graphical user interface allowing live inspection of the data in time and frequency domains. The graphical user interface can also control the IRis-core dual-comb emitter system.

IRis-core benefits

Turnkey co-aligned dual-comb system
Includes drive electronics
Controlled via
GUI on PC
Compatible with IRis-F1 spectrometer laser module

System specifications

Laser platform

Quantum Cascade Laser

Light source

Co-aligned frequency comb sources

Modularity

Yes: laser source exchangeable and compatible with IRis-F1

Center wavenumbers

2200 cm-1 (4.5μm) – 900 cm-1 (11.1μm) See the laser availability: here

Spectral coverage

typically 60 cm-1 per exchangeable laser source

Optical power

20 mW – 300 mW

Spectral resolution

<10 MHz (0.0003 cm-1)

Spectral sampling

0.16 cm-1 – 0.5 cm-1

User interface

Graphical user interface on PC platform

Detection system

Optionally available, 1 GHz bandwidth with spectrum recovery

Power consumption

110 – 230V AC, 700W typical including electronics

Cooling requirement

Cooling water with ±0.05 K stability

Optional detection system: specifications

Detector type

2x MCT

Cooling

Thermo-electrically

Bandwidth

> 900 MHz

Data acquisition

Dual-channel 14 bit data acquisition

Data processing

Spectrum-recovery to transmission or absorption. Proprietary coherent averaging algorithm optimized to reduce systematic errors including QCL specific drift correction

Data export format

HDF5 (open format)

Live data processing while acquisition

yes

What our customers say about IRis-core

IRsweep did a wonderful job outlining the laser operations for us on site and the lasers performed extremely well.

J.L., Mission Support and Test Services, USA

Laser module availability

Lasers modules of both form factors, LMA and LMC may be used in the IRis-F1. You can find the module availability here.

Comparing IRis spectrometers

IRis-F1 IRis-core IRis-C
Turn-key dual-comb spectrometer
Time resolution
1 µs
1 µs
1 ms /10 µs1 / 1 µs2
Optical power
Up to 500 mW
Up to 500 mW
50 mW typically
High resolution available (< 0.0005 cm-1)
Phase sensitive configuration available
Bay for laser module A
Bay for laser module C
With adaptor
With adaptor
Reference detector pre-aligned
Sample detector pre-aligned
Instrument purgeable
With customization
Sample path purgeable
With customization
With customization

1 with upgrade
2 with upgrade

Safety:

All statements regarding the safety of operation and technical data only apply when the instrument is operated correctly according to its specifications. The safety of any system incorporating the equipment is the responsibility of the assembler of the system. Inappropriate use of the instrument t may result in permanent eye damage. The instrument falls under the Laser Class given in the General Specifications table that is outlined by the IEC document 60825-1.
Laser Radiation: DO NOT STARE INTO BEAM; CLASS 3B LASER PRODUCT